Cogent Doors provides a comprehensive line of thick labeled doors and frames to meet all requirements for fire protection. All of Cogent door constructions conform to certified fire door procedures whether the doors are furnished with labels or not. Since label requirements vary throughout the country, local authorities having jurisdiction should be consulted during the design and planning stages.
Hardware plays the vital role in installation of fire doors. Every hardware used in the fire door has to be fire tested. We provide fire tested, CE marked quality hardware which passes the stringent tests as per BS 476 part 20 and 22.
Door leaf thickness | Infill material | Skin thickness | Fire testing duration | Max dimension | Rating Agency | Hardware | |
Wood finished | 40 mm | Ceramic Wool | 0.6 | 120 | Double door 6×8 ft | CBRI Roorkee | Yale/Dorma |
Normal finish | 40mm | Ceramic Wool | 0.6 | 120 | Double door 6×8 ft | CBRI Roorkee | Yale/Dorma |